№ 15 (ЕСБЗТ)
Permanent URI for this collection
Browse
Browsing № 15 (ЕСБЗТ) by Subject "electromag- netic compatibility"
Now showing 1 - 1 of 1
Results Per Page
Sort Options
Item The Accuracy of Traction Current Harmonics Parameters Determination by Windowed FFT(Дніпропетровський національний університет залізничного транспорту імені академіка В. Лазаряна, Дніпро, 2018) Havryliuk, Volodymyr I.EN: In the work the correct choosing of the windowed FFT parameters to achieve the necessary time and frequency resolution of the traction current spectral analysis in accordance with the re- quirements of regulatory documents has been briefly overviewed and investigations of the influence of FFT parameters on the accuracy of the determination of harmonics parameters (such as effective current, frequency, duration) have been carried out.To assess the accuracy of determining the RMS current and frequency of the harmonics, a computer study was performed using a synthesized current with known harmonics parameters, the values of which were chosen in accordance with the permissible values of the parameters determined by regulatory documents and standards.For the spectral analysis of traction current, four types of windows were selected: rectangular, Hann, Hamming and Blackman windows with duration of 0.3 and 1 s. For a sampling frequency of 27500 Hz and a window length of 0.3 s, the frequency resolution is 0.27 Hz for a rectangular window, 0.54 Hz for Hann and Hamming windows and 0.81 Hz for Blackman's window, which is consistent with the requirements of the specifications.The results of spectral analysis of traction current showed that the frequency resolution of harmonics, and accordingly the relative error in determine the frequency and the RMS value of harmonics is lower for high frequencies in spectrum.The type of windows used has a slight effect on the accuracy of determining the frequency of harmonics. The relative error of the effective value of the harmonic current was higher for a rectangular window, and relative error decreased in the row from the rectangular window to the Blackman window. The values of the relative error of the RMS current for several frequencies ofthe harmonics did not meet the requirements necessary for the practical use of the method, and this is due to spectrum leakage and scalloping.For windows with a length of 1 s, the frequency resolution of the traction current was higher. than for windows with a length of 0.3 s, and the relative error of the RMS current and frequen- cies of the harmonics were much lower, but even in this case, the relative error was high for individual frequencies .To ensure the necessary accuracy of the traction current spectral analysis with using win- dowed FFT, proper choosing of the spectral analysis parameters taking into account the traction current parameters is necessary. Taking into account a wide frequency range of traction current, a technique with variable window length and sampling frequency for different parts of the spectrum is perspective for using.