2020
Permanent URI for this community
Browse
Browsing 2020 by Author "Mashykhina, Polina B."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item 3D Modeling of Biological Wastewater Treatment in Aeration Tank(Дніпровський національний університет залізничного транспорту імені академіка В. Лазаряна, Дніпро, 2020) Biliaiev, Mykola M.; Lemesh, Maksym V.; Gunko, Olena Y.; Zadoia, Viacheslav O.; Mashykhina, Polina B.; Yakubovska, Zinaida M.ENG: Purpose. The main purpose of the article is to develop a 3D CFD model for modeling the process of biological wastewater treatment in an aeration tank. Methodology. For mathematical modeling of the process of biological wastewater treatment in the reactor, taking into account the flow hydrodynamics, geometric shape of the aeration tank, convective-diffusion transfer of the substrate and activated sludge, a 3D CFD model was built. The model is based on the three-dimensional equation of motion of an ideal liquid and the equation of mass conservation for the substrate, activated sludge. The field of sewage flow rate in the aeration tank is calculated based on the velocity potential equation. The process of biological transformation of the substrate is calculated on the basis of the Monod model. The splitting scheme was used for numerical integration of the equations of convective-diffusion transfer of activated sludge and substrate. The splitting is carried out in such a way to take into account the transfer of substrate (activated sludge) in only one direction at each step of splitting. The calculation of the unknown value of the substrate (activated sludge) concentration is carried out according to an explicit scheme. The Richardson method is used to numerically integrate the three-dimensional equation for the velocity potential, and the unknown value of the velocity potential is calculated by an explicit formula. Euler's method is used for numerical integration of equations describing the process of substrate transformation and change in activated sludge concentration (Monod model). Findings. The software implementation of the constructed 3D CFD model is carried out. A description of the structure of the developed software package is provided. The results of a computer experiment to study the process of wastewater treatment in an aeration tank with additional elements are presented. Originality. A new multifactor 3D CFD model has been developed, which allows quick assessing the efficiency of biological treatment in an aeration tank. Practical value. The constructed 3D CFD model can be used to analyze the efficiency of the aeration tank under different operating conditions at the stage of sketch design of wastewater treatment systems.Item Computer Simulation of Biological Wastewater Treatment Processes in Aerotanks With Plates(Дніпровський національний університет залізничного транспорту імені академіка В. Лазаряна, Дніпро, 2020) Biliaiev, Mykola M.; Lemesh, Maksym V.; Biliaieva, Viktoriia V.; Mashykhina, Polina B.; Yakubovska, Zinaida M.EN: Purpose. Efficiency determination of the aeration tank at the stage of design or reconstruction of bioreactors in which biological wastewater treatment is carried out requires the use of special mathematical models and calculation methods. The main purpose of the article is to develop CFD models for evaluating the operation efficiency of aeration tanks. Methodology. A numerical model has been developed for the computer calculation of the biological wastewater treatment process in aerotanks, taking into account hydrodynamics. The model is based on two-level mass conservation equations for the substrate and activated sludge and the velocity potential equation. The process of biological transformation of the substrate is calculated based on the Monod model. For the numerical integration of the mass transfer equations of activated sludge and substrate, the alternating-triangular difference splitting scheme is used. In this case, the basic equations are divided into two equations of a more simplified form. For the numerical integration of the equations for the velocity potential, it is split into two one-dimensional equations. Further, each equation is solved according to explicit scheme. For the numerical integration of equations that describe the process of substrate transformation based on the Monod model, the Euler method is used. Findings. The software implementation of the constructed numerical model has been carried out. The results of a computational experiment on the study of the wastewater treatment process in an aeration tank with plates are presented. This leads to the conclusion that the quality control of wastewater treatment in aeration tanks is possible with the help of plates. Originality. A multivariate CFD model has been developed, which makes it possible to quickly assess the efficiency of the aeration tank. A feature of the model is the ability to evaluate the operation of the aeration tank, taking into account its geometric shape and location of additional plates in the construction. Practical value. The constructed numerical model can be used during calculations in the case of designing aeration tanks, or in determining the efficiency of wastewater treatment under new operating conditions.