2020
Permanent URI for this community
Browse
Browsing 2020 by Author "Biliaieva, Viktoriia V."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Computer Simulation of Biological Wastewater Treatment Processes in Aerotanks With Plates(Дніпровський національний університет залізничного транспорту імені академіка В. Лазаряна, Дніпро, 2020) Biliaiev, Mykola M.; Lemesh, Maksym V.; Biliaieva, Viktoriia V.; Mashykhina, Polina B.; Yakubovska, Zinaida M.EN: Purpose. Efficiency determination of the aeration tank at the stage of design or reconstruction of bioreactors in which biological wastewater treatment is carried out requires the use of special mathematical models and calculation methods. The main purpose of the article is to develop CFD models for evaluating the operation efficiency of aeration tanks. Methodology. A numerical model has been developed for the computer calculation of the biological wastewater treatment process in aerotanks, taking into account hydrodynamics. The model is based on two-level mass conservation equations for the substrate and activated sludge and the velocity potential equation. The process of biological transformation of the substrate is calculated based on the Monod model. For the numerical integration of the mass transfer equations of activated sludge and substrate, the alternating-triangular difference splitting scheme is used. In this case, the basic equations are divided into two equations of a more simplified form. For the numerical integration of the equations for the velocity potential, it is split into two one-dimensional equations. Further, each equation is solved according to explicit scheme. For the numerical integration of equations that describe the process of substrate transformation based on the Monod model, the Euler method is used. Findings. The software implementation of the constructed numerical model has been carried out. The results of a computational experiment on the study of the wastewater treatment process in an aeration tank with plates are presented. This leads to the conclusion that the quality control of wastewater treatment in aeration tanks is possible with the help of plates. Originality. A multivariate CFD model has been developed, which makes it possible to quickly assess the efficiency of the aeration tank. A feature of the model is the ability to evaluate the operation of the aeration tank, taking into account its geometric shape and location of additional plates in the construction. Practical value. The constructed numerical model can be used during calculations in the case of designing aeration tanks, or in determining the efficiency of wastewater treatment under new operating conditions.Item Emergency Burning of Solid Rocket Propellant: Damage Risk Assessment to People in the Workplace(Dnipro National University of Railway Transport named after Academician V. Lazaryan, Dnipro, 2020) Biliaiev, Mykola M.; Berlov, Oleksandr V.; Biliaieva, Viktoriia V.; Kozachyna, Vitalii A.; Kalashnikov, Ivan V.EN: Purpose. This work includes the development of a computer model to calculate the risk of thermal damage to people in the shop in case of emergency burning of solid rocket propellant. Methodology. To calculate the temperature field in the shop in order to determine the zones of thermal damage to workers in the building, the equation expressing the law of energy conservation was used. Based on this modeling equation, the temperature field in the shop is calculated in the presence of a source of heat emission – burning solid rocket propellant. To calculate the velocity field of air flow in the shop, taking into account the location of obstacles in the path of heat wave propagation, we used the model of vortex-free air motion – the equation of the velocity potential. A two-step finite difference scheme of conditional approximation is used to numerically solve the equation for the velocity potential. A difference splitting scheme was used to numerically solve the energy equation. At the first stage of construction of the difference splitting scheme of the two-dimensional energy equation into the system of one-dimensional equations is performed. Each one-dimensional equation allows you to calculate the temperature change in one coordinate direction. The point-to-point computation scheme is used to determine the temperature. When conducting a computational experiment, the air exchange in the building is taken into account. The risk assessment of thermal damage to personnel in the building is performed for different probabilities of the place of emergency combustion of solid rocket propellant. Findings. Using numerical model prediction of the potential risk areas of thermal damage to staff in the shop for a variety of emergency situations was performed. Originality. A computer model for rapid assessment of the potential risk of damage to people in the shop in case of emergency burning of solid rocket propellant was constructed. Practical value. The authors developed a code that allows you to quickly simulate the temperature fields formation in the shop in case of emergency burning of solid rocket propellant and to identify potential areas of thermal damages to workers based on this information. The developed computer program can be used to assess the risk of thermal damage in the chemical industry in case of emergency.