Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://eadnurt.diit.edu.ua/jspui/handle/123456789/12405
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorBosyi, Dmytro O.en
dc.contributor.authorZemskyi, Denys R.en
dc.date.accessioned2021-01-16T07:10:54Z-
dc.date.available2021-01-16T07:10:54Z-
dc.date.issued2020-
dc.identifierDOI: 10.36137/1881E-
dc.identifier.citationBosyi D., Zemskyi D. Increasing Power Supply Efficiency for “Two WireRail” Line Consumers. Problemy Kolejnictwa. 2020. Iss. 188. P. 93–102. DOI: 10.36137/1881E.en
dc.identifier.issn0552-2145 (print)-
dc.identifier.issn2544-9451 (on-line)-
dc.identifier.urihttp://eadnurt.diit.edu.ua/jspui/handle/123456789/12405-
dc.identifier.urihttps://problemykolejnictwa.pl/images/PDF/188_1E.pdf-
dc.descriptionD. Bosyi: ORCID 0000-0003-1818-2490, D. Zemskyi: ORCID 0000-0003-4322-0727en
dc.description.abstractEN: The article is devoted to the problem of non-traction consumers power supply of AC railways. Th e low efficiency of energy transfer is caused by the design of a non-traction power supply line. Th e absence of bilateral power is typical for non-traction network 27,5 kV which consist of “two wire-rail” lines. This line is outdated technology, which does not correspond to modern requirements on the power quality, but used on AC railways with three-phase traction transformers. The purpose of the article is to investigate the methods of power supply improvements for non-traction consumers in terms of voltage unbalance, harmonic distortions and energy losses. Connection of the phasing device to delta winding traction transformer for bilateral supplying non-traction customers from network 27,5 kV is suggested in the article. The implementation of a method to increase the efficiency of electricity transmission in the non-traction network power supply allows to reduce power losses from 720 MWh / year to 441 MWh / year, the voltage unbalance from 1,9% to 1,3% and the total harmonic distortion from 8 % to 6 % respectively. Additionally, investment attractiveness of the decision was evaluated.en
dc.language.isoen-
dc.publisherInstytut Kolejnictwa, Warszawaen
dc.subjectnon-traction customersen
dc.subjecttwo wire-rail lineen
dc.subjectphase coordinatesen
dc.subjectAC railwayen
dc.subjectpower qualityen
dc.subjectКІСЕuk_UA
dc.titleIncreasing Power Supply Efficiency for “Two Wire-Rail” Line Consumersen
dc.typeArticleen
Располагается в коллекциях:Статті КІСЕ

Файлы этого ресурса:
Файл Описание РазмерФормат 
Bosyi.pdf975,59 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.